dc.contributor.author |
Perini, Ana Paula |
|
dc.contributor.author |
Neves, Lucio Pereira |
|
dc.contributor.author |
Santos, William de Souza |
|
dc.contributor.author |
Caldas, Linda Viola Ehlin |
|
dc.date.accessioned |
2019-03-19T22:14:35Z |
|
dc.date.available |
2019-03-19T22:14:35Z |
|
dc.date.issued |
2015 |
|
dc.identifier.uri |
http://hdl.handle.net/2050011876/990 |
|
dc.description.abstract |
Recently a special parallel-plate ionization chamber was developed and characterized at the Instituto de Pesquisas Energéticas e Nucleares. The operational tests presented results within the recommended limits. In order to determine the influence of some components of the ionization chamber on its response, Monte Carlo simulations were carried out. The experimental and simulation results pointed out that the dosimeter evaluated in the present work has favorable properties to be applied to 60Co dosimetry at calibration laboratories. |
pt_BR |
dc.format.extent |
4 f. |
pt_BR |
dc.language.iso |
Inglês |
pt_BR |
dc.subject.classification |
Metrologia científica e aplicada |
pt_BR |
dc.subject.classification |
Calibração |
pt_BR |
dc.subject.classification |
Metrologia e instrumentação em radiações ionizantes |
pt_BR |
dc.title |
Experimental and Monte Carlo evaluation of an ionization chamber in a 60Co beam |
pt_BR |
dc.type |
Artigo |
pt_BR |
dc.rights.license |
É permitida a reprodução deste texto e os dados nele contidos, desde que citada a fonte. Reprodução para fins comerciais são proibidas. |
pt_BR |
bom.learningResourceType |
Artigo científico |
pt_BR |
dc.mediator |
Instituto Nacional de Metrologia Qualidade e Tecnologia (INMETRO) |
pt_BR |
dc.mediator |
Sociedade Brasileira de Metrologia (SBM) |
pt_BR |
dc.rights.type |
Termo de cessão SBM |
pt_BR |
dc.subject.decs |
Metrologia |
pt_BR |
dc.subject.decs |
Metrologia científica e aplicada |
pt_BR |
dc.subject.decs |
Medição |
pt_BR |
dc.subject.decs |
Calibração |
pt_BR |
dc.subject.keyword |
Metrologia das radiações ionizantes |
pt_BR |
dc.subject.keyword |
Dosimetry |
pt_BR |
dc.subject.keyword |
Dosimetria |
pt_BR |
dc.subject.keyword |
Ionization chamber |
pt_BR |
dc.subject.keyword |
Câmara de ionização |
pt_BR |
dc.subject.keyword |
Cobalt-60 |
pt_BR |
dc.subject.keyword |
Cobalto-60 |
pt_BR |
dc.subject.keyword |
Monte Carlo method |
pt_BR |
dc.subject.keyword |
Método de Monte Carlo |
pt_BR |
dc.subject.keyword |
Instituto de Pesquisas Energéticas e Nucleares (IPEN) |
pt_BR |
dc.subject.keyword |
Universidade Federal de Uberlândia (UFU) |
pt_BR |
dc.location.country |
Brasil |
pt_BR |