dc.contributor.author |
Gonçalves, Paulo Eduardo |
|
dc.contributor.author |
Santos, William de Souza |
|
dc.contributor.author |
Belinato, Walmir |
|
dc.contributor.author |
Caldas, Linda Viola Ehlin |
|
dc.contributor.author |
Perini, Ana Paula |
|
dc.contributor.author |
Neves, Lucio Pereira |
|
dc.date.accessioned |
2019-03-13T15:58:24Z |
|
dc.date.available |
2019-03-13T15:58:24Z |
|
dc.date.issued |
2015 |
|
dc.identifier.uri |
http://hdl.handle.net/2050011876/988 |
|
dc.description.abstract |
In this paper, various simplifications of the HDR source Varian VariSource Classic model, in which 192Ir as a radionuclide is used, were compared. These simplifications were carried out by the simulation of Monte Carlo, using the MCNPX code. The different sources were compared through a distribution of energy deposition in a water phantom. Our results indicated that small simplifications will present no influence on the source response, and the removal of the entire capsule surrounding the radionuclide will present a difference of just 0.51% in the final response. |
pt_BR |
dc.format.extent |
4 f. |
pt_BR |
dc.language.iso |
Inglês |
pt_BR |
dc.subject.classification |
Metrologia científica e aplicada |
pt_BR |
dc.subject.classification |
Metrologia e instrumentação em radiações ionizantes |
pt_BR |
dc.title |
The influence of different 192Ir sources geometries to the energy deposition |
pt_BR |
dc.type |
Artigo |
pt_BR |
dc.rights.license |
É permitida a reprodução deste texto e os dados nele contidos, desde que citada a fonte. Reprodução para fins comerciais são proibidas. |
pt_BR |
bom.learningResourceType |
Artigo científico |
pt_BR |
dc.mediator |
Instituto Nacional de Metrologia Qualidade e Tecnologia (INMETRO) |
pt_BR |
dc.mediator |
Sociedade Brasileira de Metrologia (SBM) |
pt_BR |
dc.rights.type |
Termo de cessão SBM |
pt_BR |
dc.subject.decs |
Metrologia |
pt_BR |
dc.subject.decs |
Metrologia científica e aplicada |
pt_BR |
dc.subject.decs |
Medição |
pt_BR |
dc.subject.keyword |
Metrologia das radiações ionizantes |
pt_BR |
dc.subject.keyword |
Dosimetry |
pt_BR |
dc.subject.keyword |
Dosimetria |
pt_BR |
dc.subject.keyword |
192Ir source |
pt_BR |
dc.subject.keyword |
Fonte de 192Ir |
pt_BR |
dc.subject.keyword |
Brachytherapy |
pt_BR |
dc.subject.keyword |
Braquiterapia |
pt_BR |
dc.subject.keyword |
Monte Carlo method |
pt_BR |
dc.subject.keyword |
Método de Monte Carlo |
pt_BR |
dc.subject.keyword |
Instituto de Pesquisas Energéticas e Nucleares (IPEN) |
pt_BR |
dc.subject.keyword |
Universidade Federal de Uberlândia (UFU) |
pt_BR |
dc.subject.keyword |
Universidade Federal de Sergipe (UFS) |
pt_BR |
dc.location.country |
Brasil |
pt_BR |