dc.description.abstract |
Area monitoring ensures radiation exposure at an acceptable level, which must be lower than the legal limit. Experimental measurements were taken in a ionizing radiation calibration laboratory. The specified reference radiation to radiation protection N80 was used. Five area monitors were used. The ranges of dose rate inaccuracy measured in rate mode for times ≤ 2 and ≥ 3 s were from 10 to 48 % and from 1 to 15 %, respectively. The inaccuracy ranges measured in integrated mode for times ≤ 2 and ≥ 3 s were from 4 to 8 % and from 0 to 22 %, respectively. |
pt_BR |
dc.format.extent |
4 f. |
pt_BR |
dc.language.iso |
Inglês |
pt_BR |
dc.subject.classification |
Metrologia científica e aplicada |
pt_BR |
dc.subject.classification |
Calibração |
pt_BR |
dc.subject.classification |
Metrologia e instrumentação em radiações ionizantes |
pt_BR |
dc.title |
Influence of the exposure time in the area monitors at radiodiagnostic |
pt_BR |
dc.type |
Artigo |
pt_BR |
dc.rights.license |
É permitida a reprodução deste texto e os dados nele contidos, desde que citada a fonte. Reprodução para fins comerciais são proibidas. |
pt_BR |
bom.learningResourceType |
Artigo científico |
pt_BR |
dc.mediator |
Instituto Nacional de Metrologia Qualidade e Tecnologia (INMETRO) |
pt_BR |
dc.mediator |
Sociedade Brasileira de Metrologia (SBM) |
pt_BR |
dc.rights.type |
Termo de cessão SBM |
pt_BR |
dc.subject.decs |
Metrologia |
pt_BR |
dc.subject.decs |
Metrologia científica e aplicada |
pt_BR |
dc.subject.decs |
Medição |
pt_BR |
dc.subject.decs |
Calibração |
pt_BR |
dc.subject.keyword |
Metrologia das radiações ionizantes |
pt_BR |
dc.subject.keyword |
Metrologia na área de proteção radiológica |
pt_BR |
dc.subject.keyword |
Laboratório de calibração |
pt_BR |
dc.subject.keyword |
Diagnostic radiology |
pt_BR |
dc.subject.keyword |
Radiodiagnóstico |
pt_BR |
dc.subject.keyword |
Occupational exposure |
pt_BR |
dc.subject.keyword |
Exposição ocupacional |
pt_BR |
dc.subject.keyword |
Universidade do Estado da Bahia (UNEB) |
pt_BR |
dc.subject.keyword |
Instituto Federal de Educação, Ciência e Tecnologia da Bahia (IFBA) |
pt_BR |
dc.subject.keyword |
Universidade Diego Portales (UDP) |
pt_BR |
dc.subject.keyword |
Universidade de Tarapacá (UTA) |
pt_BR |
dc.location.country |
Brasil |
pt_BR |