dc.contributor.author |
Trigo, Leonardo |
|
dc.contributor.author |
Slomovitz, Daniel |
|
dc.contributor.author |
Kyriazis, Gregory Amaral |
|
dc.date.accessioned |
2018-11-27T15:43:30Z |
|
dc.date.available |
2018-11-27T15:43:30Z |
|
dc.date.issued |
2017 |
|
dc.identifier.uri |
http://hdl.handle.net/2050011876/808 |
|
dc.description.abstract |
This paper describes a voltage-ratio measuring system up to 50 kHz. It is based on two Keysight 3458A digital multimeters, working in DCV sampling mode. An external trigger based on a rubidium clock, drives both digital multimeters. |
pt_BR |
dc.format.extent |
4 f. |
pt_BR |
dc.language.iso |
Inglês |
pt_BR |
dc.subject.classification |
Metrologia científica e aplicada |
pt_BR |
dc.subject.classification |
Metrologia física |
pt_BR |
dc.subject.classification |
Metrologia |
pt_BR |
dc.title |
Voltage-ratio calibration system up to 50 kHz |
pt_BR |
dc.type |
Artigo |
pt_BR |
dc.rights.license |
É permitida a reprodução deste texto e os dados nele contidos, desde que citada a fonte. Reprodução para fins comerciais são proibidas. |
pt_BR |
bom.learningResourceType |
Artigo científico |
pt_BR |
dc.mediator |
Instituto Nacional de Metrologia Qualidade e Tecnologia (INMETRO) |
pt_BR |
dc.mediator |
Sociedade Brasileira de Metrologia (SBM) |
pt_BR |
dc.rights.type |
Termo de cessão SBM |
pt_BR |
dc.subject.decs |
Metrologia |
pt_BR |
dc.subject.decs |
Metrologia científica e aplicada |
pt_BR |
dc.subject.decs |
Metrologia em energia elétrica |
pt_BR |
dc.subject.decs |
Medição |
pt_BR |
dc.subject.decs |
Calibração |
pt_BR |
dc.subject.keyword |
Ratio measurement |
pt_BR |
dc.subject.keyword |
Sampling |
pt_BR |
dc.subject.keyword |
Digital multimeter |
pt_BR |
dc.subject.keyword |
Administración Nacional de Usinas y Trasmisiones Eléctricas (UTE) |
pt_BR |
dc.location.country |
Brasil |
pt_BR |