Abstract:
Nondestructive tests are widely used in various sectors of industry, and its main techniques are based on the use of ultrasound. The flaw detector is a device used in ultrasonic testing. In this article, it is studied the influence of the flaw detection settings on the measurement result. It was observed that when the speed of sound and the thickness of the standard block are known, the equipment gives the best results, with a maximum error of 0.08%. The results show the importance of having a standard block calibrated in order to minimize errors.